Therapeutic role of Vitamin B12 in patients of chronic tinnitus: A pilot study
Charu Singh, Rahul Kawatra, Jaya Gupta, Vishnu Awasthi, Homnath Dungana
March-April 2016, 18(81):93-97
DOI
:10.4103/1463-1741.178485
PMID
:26960786
True tinnitus is a phantom auditory perception arising from a source or trigger in the cochlea, brainstem, or at higher centers and has no detectable acoustic generator. The most accepted is the famous neurophysiologic model of Jastreboff, which stresses that tinnitus, is a subcortical perception and results from the processing of weak neural activity in the periphery. The aim of this study is to determine the role of Vitamin B12 in treatment of chronic tinnitus. In this randomized, double-blind pilot study, total 40 patients were enrolled, of which 20 in Group A (cases) received intramuscular therapy of 1 ml Vitamin B12 (2500 mcg) weekly for a period of 6 weeks and Group B (20) patients received placebo isotonic saline 01 ml intramuscular. The patients were subjected to Vitamin B12 assay and audiometry pre- and post-therapy. Of the total patients of tinnitus, 17 were Vitamin B12 deficient that is 42.5% showed deficiency when the normal levels were considered to be 250 pg/ml. A paired
t
-test showed that in Group A, patients with Vitamin B12 deficiency showed significant improvement in mean tinnitus severity index score and visual analog scale (VAS) after Vitamin B12 therapy. This pilot study highlights the significant prevalence of Vitamin B12 deficiency in North Indian population and improvement in tinnitus severity scores and VAS in cobalamin-deficient patients receiving intramuscular Vitamin B12 weekly for 6 weeks further provides a link between cobalamin deficiency and tinnitus thereby suggestive of a therapeutic role of B12 in cobalamin-deficient patients of tinnitus.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[CITATIONS]
[PubMed]
15,072
41
12
CASE REPORT
Call centers and noise-induced hearing loss
Ayse Coskun Beyan, Yucel Demiral, Arif Hikmet Cimrin, Alparslan Ergor
March-April 2016, 18(81):113-116
DOI
:10.4103/1463-1741.178512
PMID
:26960789
Noise is defined as unwelcome sound. It has been estimated that 16% of adult hearing loss in the world is due to noise exposure at the workplace. This report offers a case that diagnosed with hearing loss of whom working as a call center operator at home. Home agent operators should be explored.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[CITATIONS]
[PubMed]
10,622
42
17
ARTICLES
Exposure-response relationship of wind turbine noise with self-reported symptoms of sleep and health problems: A nationwide socioacoustic survey in Japan
Takayuki Kageyama, Takashi Yano, Sonoko Kuwano, Shinichi Sueoka, Hideki Tachibana
March-April 2016, 18(81):53-61
DOI
:10.4103/1463-1741.178478
PMID
:26960782
The association of wind turbine noise (WTN) with sleep and physical/mental health has not been fully investigated. To investigate the relationship of WTN with the prevalence of self-reported symptoms of sleep and health problems, a socioacoustic survey of 1079 adult residents was conducted throughout Japan (2010-2012): 747 in 34 areas surrounding wind turbine plants and 332 in 16 control areas. During face-to-face interviews, the respondents were not informed of the purpose of the survey. Questions on symptoms such as sleeplessness and physical/mental complaints were asked without specifying reasons. Insomnia was defined as having one or any combination of the following that occurs three or more times a week and bothers a respondent: Difficulty initiating sleep, difficulty maintaining sleep, premature morning awakening, and feeling of light overnight sleep. Poor health was defined as having high scores for health complaints, as determined using the Total Health Index, exceeding the criteria proposed by the authors of the index. The noise descriptor for WTN was
L
Aeq,n
outdoor, estimated from the results of actual measurement at some locations in each site. Multiple logistic analysis was applied to the
L
Aeq,n
and insomnia or poor health. The odds ratio (OR) of insomnia was significantly higher when the noise exposure level exceeded 40 dB, whereas the self-reported sensitivity to noise and visual annoyance with wind turbines were also independently associated with insomnia. OR of poor health was not significant for noise exposure, but significant for noise sensitivity and visual annoyance. The above two moderators appear to indicate the features of respondents who are sensitive to stimuli or changes in their homeostasis.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[CITATIONS]
[PubMed]
10,196
51
13
Comparison of staff and family perceptions of causes of noise pollution in the Pediatric Intensive Care Unit and suggested intervention strategies
Harsheen Kaur, Gina M Rohlik, Michael E Nemergut, Sandeep Tripathi
March-April 2016, 18(81):78-84
DOI
:10.4103/1463-1741.178480
PMID
:26960784
Noise and excessive, unwanted sound in the Pediatric Intensive Care Unit (PICU) is common and has a major impact on patients' sleep and recovery. Previous research has focused mostly on absolute noise levels or included only staff as respondents to acknowledge the causes of noise and to plan for its reduction. Thus far, the suggested interventions have not ameliorated noise, and it continues to serve as a barrier to recovery. In addition to surveying PICU providers through internet-based software, patients' families were evaluated through in-person interviews utilizing a pretested instrument over 3 months. Families of patients admitted for more than 24 h were considered eligible for evaluation. Participants were asked to rank causes of noise from 1 to 8, with eight being highest, and identified potential interventions as effective or ineffective. In total, 50 families from 251 admissions and 65 staff completed the survey. Medical alarms were rated highest (mean ± standard deviation [SD], 4.9 ± 2.1 [2.8-7.0]), followed by noise from medical equipment (mean ± SD, 4.7 ± 2.1 [2.5-6.8]). This response was consistent among PICU providers and families. Suggested interventions to reduce noise included keeping a patient's room door closed, considered effective by 93% of respondents (98% of staff; 88% of families), and designated quiet times, considered effective by 82% (80% of staff; 84% of families). Keeping the patient's door closed was the most effective strategy among survey respondents. Most families and staff considered medical alarms an important contributor to noise level. Because decreasing the volume of alarms such that it cannot be heard is inappropriate, alternative strategies to alert staff of changes in vital signs should be explored.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[CITATIONS]
[PubMed]
8,427
31
6
Comparison of direct measurement methods for headset noise exposure in the workplace
Flora G Nassrallah, Christian Giguere, Hilmi R Dajani, Nicolas N Ellaham
March-April 2016, 18(81):62-77
DOI
:10.4103/1463-1741.178479
PMID
:26960783
The measurement of noise exposure from communication headsets poses a methodological challenge. Although several standards describe methods for general noise measurements in occupational settings, these are not directly applicable to noise assessments under communication headsets. For measurements under occluded ears, specialized methods have been specified by the International Standards Organization (ISO 11904) such as the microphone in a real ear and manikin techniques. Simpler methods have also been proposed in some national standards such as the use of general purpose artificial ears and simulators in conjunction with single number corrections to convert measurements to the equivalent diffuse field. However, little is known about the measurement agreement between these various methods and the acoustic manikin technique. Twelve experts positioned circum-aural, supra-aural and insert communication headsets on four different measurement setups (Type 1, Type 2, Type 3.3 artificial ears, and acoustic manikin). Fit-refit measurements of four audio communication signals were taken under quiet laboratory conditions. Data were transformed into equivalent diffuse-field sound levels using third-octave procedures. Results indicate that the Type 1 artificial ear is not suited for the measurement of sound exposure under communication headsets, while Type 2 and Type 3.3 artificial ears are in good agreement with the acoustic manikin technique. Single number corrections were found to introduce a large measurement uncertainty, making the use of the third-octave transformation preferable.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[CITATIONS]
[PubMed]
8,112
31
2
Noise and sleep on board vessels in the Royal Norwegian Navy
Erlend Sunde, Magne Bratveit, Stale Pallesen, Bente Elisabeth Moen
March-April 2016, 18(81):85-92
DOI
:10.4103/1463-1741.178481
PMID
:26960785
Previous research indicates that exposure to noise during sleep can cause sleep disturbance. Seamen on board vessels are frequently exposed to noise also during sleep periods, and studies have reported sleep disturbance in this occupational group. However, studies of noise and sleep in maritime settings are few. This study's aim was to examine the associations between noise exposure during sleep, and sleep variables derived from actigraphy among seamen on board vessels in the Royal Norwegian Navy (RNoN). Data were collected on board 21 RNoN vessels, where navy seamen participated by wearing an actiwatch (actigraph), and by completing a questionnaire comprising information on gender, age, coffee drinking, nicotine use, use of medication, and workload. Noise dose meters were used to assess noise exposure inside the seamen's cabin during sleep. Eighty-three sleep periods from 68 seamen were included in the statistical analysis. Linear mixed-effects models were used to examine the association between noise exposure and the sleep variables percentage mobility during sleep and sleep efficiency, respectively. Noise exposure variables, coffee drinking status, nicotine use status, and sleeping hours explained 24.9% of the total variance in percentage mobility during sleep, and noise exposure variables explained 12.0% of the total variance in sleep efficiency. Equivalent noise level and number of noise events per hour were both associated with increased percentage mobility during sleep, and the number of noise events was associated with decreased sleep efficiency.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[CITATIONS]
[PubMed]
7,177
29
18
Student's music exposure: Full-day personal dose measurements
Nilesh Jeevandas Washnik, Susan L Phillips, Sandra Teglas
March-April 2016, 18(81):98-103
DOI
:10.4103/1463-1741.178510
PMID
:26960787
Previous studies have shown that collegiate level music students are exposed to potentially hazardous sound levels. Compared to professional musicians, collegiate level music students typically do not perform as frequently, but they are exposed to intense sounds during practice and rehearsal sessions. The purpose of the study was to determine the full-day exposure dose including individual practice and ensemble rehearsals for collegiate student musicians. Sixty-seven college students of classical music were recruited representing 17 primary instruments. Of these students, 57 completed 2 days of noise dose measurements using Cirrus doseBadge programed according to the National Institute for Occupational Safety and Health criterion. Sound exposure was measured for 2 days from morning to evening, ranging from 7 to 9 h. Twenty-eight out of 57 (49%) student musicians exceeded a 100% daily noise dose on at least 1 day of the two measurement days. Eleven student musicians (19%) exceeded 100% daily noise dose on both days. Fourteen students exceeded 100% dose during large ensemble rehearsals and eight students exceeded 100% dose during individual practice sessions. Approximately, half of the student musicians exceeded 100% noise dose on a typical college schedule. This finding indicates that a large proportion of collegiate student musicians are at risk of developing noise-induced hearing loss due to hazardous sound levels. Considering the current finding, there is a need to conduct hearing conservation programs in all music schools, and to educate student musicians about the use and importance of hearing protection devices for their hearing.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[CITATIONS]
[PubMed]
6,706
34
15
Effect of personal music system use on sacculocollic reflex assessed by cervical vestibular-evoked myogenic potential: A preliminary investigation
Niraj Kumar Singh, Chithra Sobha Sasidharan
March-April 2016, 18(81):104-112
DOI
:10.4103/1463-1741.178511
PMID
:26960788
Listening to music through a portable personal music system (PMS) is a growing trend, especially among the youth. The preferred listening level in such kinds of PMS has been reported to cross the safe levels and its impact on the auditory system was demonstrated in several previous investigations. Owing to the commonality in several aspects between the auditory and the vestibular systems, it appears likely that the deleterious effects of PMS use could also be impinging on the vestibular system, which has never been investigated. The present study therefore, aimed at evaluating the effects of PMS use on the sacculocollic reflex assessed by the cervical vestibular-evoked myogenic potential (cVEMP) technique. Thirty-two regular PMS users and 32 nonregular PMS users underwent cVEMP testing using alternating polarity 500 Hz tone bursts. The results revealed no significant group difference in latencies and interaural asymmetry ratio. However, the cVEMP was significantly reduced in the group of individuals in whom the diffused field equivalent sound pressure levels (SPLs) were above the damage risk criteria (DRC) compared to those with diffused field equivalent SPLs below it (
P
< 0.01). Therefore, the use of PMS at high levels of volume controls could be deleterious to the vestibular well-being of an individual.
[ABSTRACT]
[FULL TEXT]
[PDF]
[Mobile Full text]
[EPub]
[CITATIONS]
[PubMed]
6,096
29
3
Contact us
|
Sitemap
|
Advertise
|
What's New
|
Ahead Of Print
|
Feedback
|
Copyright and Disclaimer
|
Privacy Notice
© 2007 - Noise & Health | Published by Wolters Kluwer -
Medknow
Online since 1
st
May, 2007