Year : 2015  |  Volume : 17  |  Issue : 78  |  Page : 364--373

Measurement of impulse peak insertion loss from two acoustic test fixtures and four hearing protector conditions with an acoustic shock tube

William J Murphy1, Cameron J Fackler2, Elliott H Berger4, Peter B Shaw1, Mike Stergar4 
1 Division of Applied Research and Technology, National Institute for Occupational Safety and Health, Cincinnati, Ohio, USA
2 Division of Applied Research and Technology, National Institute for Occupational Safety and Health, Cincinnati, Ohio; 3M E-A-RCAL Laboratory, Indianapolis, Indiana, USA

Correspondence Address:
William J Murphy
Hearing Loss Prevention Team, National Institute for Occupational Safety and Health, 1090 Tusculum Ave. MS C-27, Cincinnati OH 45226-1998
USA

Impulse peak insertion loss (IPIL) was studied with two acoustic test fixtures and four hearing protector conditions at the E-A-RCAL Laboratory. IPIL is the difference between the maximum estimated pressure for the open-ear condition and the maximum pressure measured when a hearing protector is placed on an acoustic test fixture (ATF). Two models of an ATF manufactured by the French-German Research Institute of Saint-Louis (ISL) were evaluated with high-level acoustic impulses created by an acoustic shock tube at levels of 134 decibels (dB), 150 dB, and 168 dB. The fixtures were identical except that the E-A-RCAL ISL fixture had ear canals that were 3 mm longer than the National Institute for Occupational Safety and Health (NIOSH) ISL fixture. Four hearing protection conditions were tested: Combat Arms earplug with the valve open, ETYPlugs ® earplug, TacticalPro headset, and a dual-protector ETYPlugs earplug with TacticalPro earmuff. The IPILs measured for the E-A-RCAL fixture were 1.4 dB greater than the National Institute for Occupational Safety and Health (NIOSH) ISL ATF. For the E-A-RCAL ISL ATF, the left ear IPIL was 2.0 dB greater than the right ear IPIL. For the NIOSH ATF, the right ear IPIL was 0.3 dB greater than the left ear IPIL.


How to cite this article:
Murphy WJ, Fackler CJ, Berger EH, Shaw PB, Stergar M. Measurement of impulse peak insertion loss from two acoustic test fixtures and four hearing protector conditions with an acoustic shock tube.Noise Health 2015;17:364-373


How to cite this URL:
Murphy WJ, Fackler CJ, Berger EH, Shaw PB, Stergar M. Measurement of impulse peak insertion loss from two acoustic test fixtures and four hearing protector conditions with an acoustic shock tube. Noise Health [serial online] 2015 [cited 2023 Sep 22 ];17:364-373
Available from: https://www.noiseandhealth.org/article.asp?issn=1463-1741;year=2015;volume=17;issue=78;spage=364;epage=373;aulast=Murphy;type=0