Home Email this page Print this page Bookmark this page Decrease font size Default font size Increase font size
Noise & Health  
 CURRENT ISSUE    PAST ISSUES    AHEAD OF PRINT    SEARCH   GET E-ALERTS    
 
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
Email Alert *
Add to My List *
* Registration required (free)  
 


 
   Abstract
   Nocturnal aircra...
   Maximum noise le...
   Assessment of th...
   The reliability ...
   Calculation of t...
   The onset thresh...
   Evaluations of r...
   Discussion
   References
   Article Figures
   Article Tables
 

 Article Access Statistics
    Viewed8594    
    Printed270    
    Emailed0    
    PDF Downloaded165    
    Comments [Add]    
    Cited by others 5    

Recommend this journal

 


 
ARTICLES Table of Contents   
Year : 2004  |  Volume : 6  |  Issue : 24  |  Page : 21-33
Nocturnal awakenings due to aircraft noise*. Do wake-up reactions begin at sound level 60 dB(A)?

1 Interdisciplinary Research Network Noise and Health, Berliner Zentrum Public Health, Berlin, Germany
2 Robert-Koch-Institut, Berlin FG22 Section Environmental Medicine, Germany

Click here for correspondence address and email
 
  Abstract 

Night-time wake-up thresholds at noise levels of 60 dB(A) are frequently employed in Germany to establish "noise polluted areas". The criterion is, however, based on an incorrect processing of statistical data gathered from an evaluation of literature performed by Griefahn et al. (1976). This finding has emerged from an extensive revision of the study. Using appropriate statistical methods, maximum levels of under 48 dB(A) are assessed as waking-up thresholds at ear level in sleeping persons, in contrast to maximum levels of 60 dB(A) calculated by Griefahn et al. in 1976. The linear dose-response relationship, which in the course of the revision could be derived from the early publications, agrees with the results of more recent literature evaluations. The present contribution is not intended to give rise to the question whether in the interest of medical prevention it is reasonable to develop night-time protective policies merely founded on noise levels marking the "statistical" onset of nocturnal wake-up reactions. In this context, emphasis is laid on the deformation of the biological rhythm of sleep.

Keywords: Noise effects - Sleep disturbances - Wake-up frequencies - Immission limit values - Health risks.

How to cite this article:
Maschke C, Hecht K, Wolf U. Nocturnal awakenings due to aircraft noise*. Do wake-up reactions begin at sound level 60 dB(A)?. Noise Health 2004;6:21-33

How to cite this URL:
Maschke C, Hecht K, Wolf U. Nocturnal awakenings due to aircraft noise*. Do wake-up reactions begin at sound level 60 dB(A)?. Noise Health [serial online] 2004 [cited 2023 Mar 26];6:21-33. Available from: https://www.noiseandhealth.org/text.asp?2004/6/24/21/31658

  Nocturnal aircraft noise and taking preventive action Top


Nocturnal aircraft noise induces activations of the vegetative nervous system, as is confirmed by several independent investigations of the last 35 years. Noise-induced activations may interfere with normal sleep stages und cause awakenings. Undisturbed sleep brings about health, well-being, efficiency, and optimism. Long-term sleep disturbances, however, may induce adverse health effects of various kinds and intensities.

The necessity of taking preventive action is in Germany generally acknowledged (e.g. (SVRU 1999)). But there is still disagreement regarding guideline immission values below which adverse sleep disturbances are most probably avoided.

Notwithstanding numerous investigations, the question of adequate health-related immission regulations to avoid not rested sleep can still not be answered conclusively. This may have serious consequences with regard to establishing "noise polluted areas", as has become evident from calculations instigated by the mediation procedures in connection with the Frankfurt/Main Airport area extensions (MV­Frankfurt/Main 1999). In [Figure - 1], the perimeters of several night-time noise exposed areas around Frankfurt/Main Airport are outlined according to calculations by the Hessian Office for the Environment (Hessische Landesanstalt fdr Umwelt) as based on critical thresholds determined by each Jansen, Griefahn, and Maschke. There is no substantial difference between the contours according to (2) Griefahn and (3) Maschke. Outlined by contour (1), however, the night-time noise polluted area according to Jansen imposes as several times smaller.

The reason for this remarkable discrepancy is Jansen's demand ((Jansen et al. 1995) pp. 92 and 105, (Jansen 2000a) p. 106) that noise protection measures ought to be founded on the "proven" results of German noise effect research of the earlier years.

The main outcome of German research in earlier years is the night-time noise protection criterion 6 x 60 dB(A), based on investigations by Jansen (e.g. (Jansen 1970)) and Griefahn (Griefahn et al. 1976). This criterion implies that nocturnal noise exposures are a risk to health if six flight events or more per night with maximum levels of 60 dB(A) or above occur in a person's bedroom. According to the criterion, aircraft noise exposures below a maximum noise level of 60 dB(A) in the bedroom are regarded as tolerable and not adverse to health. As Jansen points out, noise-induced awakenings begin at a mean group value of 60 dB(A) at ear level of a sleeping person:

"The wake-up reaction indicates a disturbance of the normal balance regulation. Consequently, the dose-response relationship between awakenings and sound levels constitutes a criterion of health hazards and serves as a reliable indicator (...). The zero point of this dose-response relationship is (according to Griefahn et al. 1976) established at a maximum sound level value of 60 dB(A) (...). With a standard deviation of ±7, individual awakenings at sound level values between 53 and 67 dB(A) have to be accounted for" ((Jansen 2000b), p.47/48, underlinings by Maschke et al.).

The awakening threshold at 60 dB(A) is by Jansen (e.g. in (Jansen et al. 1995)) defined as a "statistical" threshold as opposed to individual wake-up thresholds. This was supported by an extensive evaluation of investigations in the field of "sleep and noise" carried out by Griefahn, Jansen and Klosterkotter in 1976 (Griefahn et al. 1976). In the framework of the project approval proceedings (Planfeststellungsverfahren) on behalf of the Berlin/Brandenburg International Airport, this study has been submitted to a critical review (Maschke et al. 2000). The results are summarized in the present contribution.

In order to improve reading the article, quotations are printed in italics. Formatting used in the originals were disregarded. Insertions and obliterations within the quotations are marked by (square brackets). Furthermore, it was unavoidable to develop statistical proofs which for the critical reader are available from the authors.


  Maximum noise levels and awakening frequencies according to Griefahn et al. 1976 Top


In 1976, Griefahn et al. published a linear dose ­response relationship between night-time maximum noise levels and awakening frequencies (Griefahn et al. 1976), given by the straight line in [Figure - 2]. According to this dose ­response relationship, the onset threshold of noise-induced awakenings is determined at a maximum level of 60 dB(A). This dose-response relationship ensued from a literature evaluation of 10 out of 19 publications dated before 1976. A number of these publications contained sub-­studies, each dealing with noise induced awakenings and varying factors like gender and age of test persons or the number of noise events. The strong variability in awakening frequencies in the 24 sub-studies, which in many cases included repeated measurements (see data points in [Figure - 3]), was fitted by a straight line.

The research results of Steinicke and Gadeke et al. (Steinicke 1957; Gadeke 1969), were disregarded by both Griefahn et al. and the present revision study because of reservations regarding their design. Both investigations were carried out with longer lasting noises. Steinicke (1957) exposed his probands in the early morning hours to a steadily increasing noise from a woodcutting machine until they signaled awakening. Gadeke et al. (1969) exposed 3 to 63 months old infants to noises comparable to factory noises.

One cannot, with certainty, infer the baseline data set from the straight line depicted in [Figure - 2]. It is good scientific practice to give the baseline data set along with the trend, in this case the straight line. In [Figure - 3], the studies which Griefahn et al. referred to in their literature evaluation ((Griefahn et al. 1976), attachment 4) are presented as a data point cloud. Children up to the age of 18 and old persons from 69 years up were depicted separately.

The distribution of the data values over the graph does indeed suggest that children and old persons should not be evaluated together with adults, but ought to be considered separately as was proposed, among others, by Hecht and Maschke (e.g. (Hecht et al. 1999)). Yet, considerable differences in awakening frequencies at identical maximum noise levels were equally found in the groups of adults of the sub-studies.

The altogether heterogeneous data set in [Figure - 3] was by Griefahn et al. further reduced for formal points of view. Therefore, all investigations were excluded which did not contain repeated measurements. Also, "the very old of the study published by Lukas et al. (…) in 1969 were not included in further calculations", since the results were based on considerably changing numbers of over flights. "Also, the awakening frequency in children taken from the investigations of Lukas et al. (1969, 1971) were not further included because they amounted to Zero within the (whole) tested intensity range" ((Griefahn et al. 1976), p.68). The awakening frequencies of the remaining sub-studies are, together with the straight line according to Griefahn et al., inserted in [Figure - 4].

For the well-trained observer, a discrepancy between the data points and the straight line according to Griefahn is discernable in this graph. The discrepancy becomes evident for the reader who visually averages the awakening frequencies within smaller maximum level ranges around 60, 70, 80 and 100 dB(A), and then draws an imaginary straight line to adjust the mean values. Such an estimated best fit line (dotted line in [Figure - 4]) runs much lower than the straight line according to Griefahn et al., and does not cut the x-axis at 60 dB(A).

As regards the discrepancy between the data point cloud and the straight line according to Griefahn, it must be taken into account that each data point represents a mean average value of different subordinate data sets (e.g. identical groups of individuals tested at different maximum sound levels). Such dependencies in the data sets as well as differing numbers of probands in each test series may be responsible for the observed discrepancy.


  Assessment of the best fit line according to Griefahn Top


The problem of jointly calculating dependent and independent mean values in one regression analysis has been solved by Griefahn et al. (1976) by restricting the analysis to the greater number of dependent data sets and to calculate separate regression lines for each of the dependent data series. In a second step, each individual regression line was weighted by the number of persons and then all regression lines averaged. As can be seen in [Figure - 5], the resulting individual regression lines are found in quite different level ranges. In order to adjust the lines, Griefahn et al. extrapolated each individual regression line across the level range 20-120 dB(A), and then averaged the values of the regression lines within this level range.

For averaging the regression lines, the dependent data series were weighted according to the diverse numbers of test persons. In this context, Griefahn et al. state as follows:

"Based on each single trend, the expected relative reaction frequency was then calculated for the intensity range 20 dB(A) to 120 dB(A). Weighting all individual values by the number of probands, each according to their respective test series, a mean intensity value was calculated from the relevant data. The trend of wake-up frequencies derived from these mean values is given (as fit line) ((Griefahn et al. 1976), p. 68­ 69)".

Weighting the regression lines in [Figure - 5] by the number of probands and then averaging the lines, the revision resulted in a straight line of the equation y = 1.315x - 78.827 (see [Figure - 6]). This agrees with the equation y = 1.30x - 78.41 as calculated by Griefahn et al. in 1976. The small differences may be ascribed to rounded data which in the process of the revision were added from attachment 4 of (Griefahn et al. 1976), and also to slightly differing numbers of probands. Whereas Griefahn et al. stated a total of 94 test persons ((Griefahn et al. 1976); [Figure - 9]), the revision study comprised 98 test persons.


  The reliability of the best fit line according to Griefahn Top


A best fit line is supposed to represent the total of all single data points. Spontaneously, one should think that an appropriate best fit line ought to be drawn in such a way that the sum of predictable errors (deviations from each single data point) is kept as small as possible.

Proceeding that way, however, values with greater distances from the main tendency exert only little influence on the best fit line. In this case, the best fit line cannot be representative of all data points. Therefore, instead of the sum of deviations, the sum of the least square errors has to be minimized. A straight line which meets the criterion of the least square errors is obtained by a linear regression analysis yielding a regression line. It is internationally agreed that linear dose­ response relationships are obtained by linear regression provided that the independent variable is to be considered as (near to) faultless. This requirement is met by sound level measurements. The best fit line calculated by the authors Griefahn et al. (1976) does not meet the requirement of the least square error minimization and therefore cannot be interpreted as a usual dose-response relationship, as was repeatedly published by the authors. The method of averaging individual regression lines does on principle result in a straight line. But a regression line claiming to be representative of an entire data set can only be derived under the following conditions (statistical proof is available from the authors):

1. The number of data points of all data sets must be in agreement (n 1 = n 2 = n i ), otherwise a weighted averaging has to be carried out.

2. The variance of the tested maximum levels (of the independent values) must be in agreement ((var(x 1 ) = var(x2) = var(xi)).

3. The mean values of the tested maximum sound levels must be in agreement ( x1= x2 = xi )

As is shown in [Table - 1], the requirements 2 and 3 are not met by the given data set. The variance of the maximum levels (independent data series) fluctuates between 16 and 100 dB(A) 2 . The mean values of the maximum levels fluctuate between 55 and 110 dB(A).

In the case of the given data set, containing extremely varying mean values and variances, the method of averaging the individual regression line employed by the authors does lead to a straight line, but not to a regression line representing the complete data set. In all probability, such severe violation of the above prerogatives has led to a straight line which considerably diverges from the regression line based on the entire data set.


  Calculation of the regression line based on the complete data set Top


The regression line based on the entire data set (each data point representing a mean average value; the individual parameters being unknown) can be calculated by customary linear regression, providing it is possible to convert the dependent mean values into virtually independent data points. Such a procedure, as was indirectly also adopted by Griefahn et al. (1976), consists in distributing equal numbers of probands, who were repeatedly measured within one test series, over the number of the repeat measurements. If for example the same 12 persons were tested for three sound level intensities, then each averaged data point is weighted by 12/3 = 4 (statistical background available from the authors). This procedure ensures that a dependent data series is only weighted by the number of test persons and not by the total number of measurements. The procedure corresponds with the weighting by persons which was used by Griefahn et al. in 1976 for averaging the individual regression lines. The commonly used regression over all "person-weighted" data points leads to results identical with the averaged individual regression lines, if the individual regression lines fulfill all statistical requirements to allow averaging.

The splitting of test persons within the repeated measurements is however not tied to identical variances or mean values of maximum levels as was the case when averaging the regression lines.

If a linear regression is calculated from data points "weighted by persons", a significant regression line ensues as is demonstrated in [Figure - 7]. The number of sub-studies und the number of test persons is greater than those according to Griefahn et al. (1976). At this point it was possible to include those sub-studies from attachment 4 into the regression, which did not contain repeated measurements and which therefore did not allow calculation of individual regression lines. These sub-studies had been excluded from the analyses by Griefahn et al. in 1976. For comparison, the regression line based on the same data set, but ignoring the dependency of the sub-studies has been added in [Figure - 7].


  The onset threshold of noise-induced awakenings Top


The straight line developed and published by Griefahn, Jansen and Klosterkotter in 1976 (Griefahn et al. 1976) diverges considerably from the regression line based on the same data set [Figure - 8] and can therefore not be employed for limit value regulations. The difference becomes all the more evident when examining the onset thresholds of noise-induced awakenings. According to the straight line of Griefahn et al. (1976), noise-induced awakenings begin "statistical" at a maximum noise level of 60 dB(A). Taking into account the regression line calculated from the data points "weighted by persons", a wake-up frequency of already more than 10% is reached at the maximum noise level 60 dB(A).

A "statistical" noise-induced awakening threshold (as is frequently used in Germany) cannot directly be derived from the regression line based on "person-weighted" data points, because the point of intersection with the x-axis (0% wake-up frequency) can only be determined by extrapolation of the regression line. An extrapolation, however, is statistically unreliable. The one question which can statistically be answered is whether there exists a level range in which, for the given data set, a "statistical" awakening threshold of sufficient reliability may be expected. The answer is given by the confidence interval of the regression line.

[Figure - 9] shows the regression line across the data points "weighted by persons", displaying a 95%-confidence interval.

The 95%-confidence interval in this scattered graph demonstrates that the "statistical" onset threshold of noise-induced awakenings is to be expected in the level range 0-48 dB(A), according to the given data set. Examining the maximum noise levels marking the "statistical" onset of noise-induced awakenings according to the given data set, they are clearly to be assessed (with a reliability of 95%) at a maximum noise level of about 48 dB(A), i.e. the intersection point of the lower confidence interval and the x axis (0% wake-up frequency), but not at 60 dB(A).

As the revision has shown, the statement that noise-induced awakenings statistically begin at a maximum noise level of 60 dB(A) cannot be verified by the literature evaluation by Griefahn et al. (1976).


  Evaluations of recent literature Top


Large-scale evaluations of literature concerned with noise-induced sleep disturbances were in recent years published by Hofman (Hofman 1994), Maschke (Maschke 1997) and the Health Council of the Netherlands (Gezondheidsraad 1999) among others. Hofman has only taken into consideration studies which refer to realistic environmental noises (flight noises, road traffic noises). From her study, Hofman concludes that under realistic noise exposure conditions, aircraft noise of moderate maximum levels results in a greater probability of awakenings than was stated by Griefahn et al. in 1976. In particular, road traffic noise and flight noise ought to be investigated separately. The results are given in [Figure - 10]. For comparison, Griefahn's straight line is added as a dotted line.

Regarding aircraft noise, the study of Hofman does not yield a reliable dose-response relationship with noise-induced waking-up reactions. The reliability of the regression line calculated by Hofman must by itself be rated as insignificant (R 2 = 0.074). On the other hand, the regression line calculated from real flight noises (y = 0.4362x - 9.1415) agrees in tendency with the revised regression line based on the data set of Griefahn et al. 1976 (y = 0.39x - 12.869).

Both regression lines as well as the fitting line according to Griefahn are depicted in [Figure - 11].

According to Griefahn et al. (1976), the statistical value of wake-up frequencies is 0% at the maximum sound level 60 dB(A). The revision of this literature evaluation yielded a statistical value of awakening frequencies of 10%, and the study of Hofman (1994) states a statistical value of about 17% in awakening frequencies. Commissioned by the German Federal Environmental Agency, Maschke et al. (1997) critically reviewed 28 experimental primary studies published since 1980. They equally conclude that quasi-continuous noises and intermittent (flight) noises must be separated. For intermittent road traffic noises they found an effect threshold of stimulated awakening reactions of Lmax = 45 dB(A). Under the term stimulated awakening reactions, Maschke et al. (1997) registered all reactions observed within a short time window following a noise event. The time windows varied from 30 to 90 seconds in various experiments. The studies also demonstrates that memorized awakening reactions (often documented in field studies) were only assessed at levels higher than "physiologically" detectable wake-up reactions, as for instance by encephalogram.

In the publication "Public health impact of large airports" of the Netherlands Health Council (Gezondheidsraad 1999), based on data from an evaluation of literature, a sound exposure level (SEL) of 50 dB(A) at the ear of a sleeping person is determined as the onset point of awakenings. This value corresponds with a maximum noise level event of Lmax ˜ 43 dB(A) for a 10-dB downtime of 10 seconds.


  Discussion Top


Nocturnal flight noise induces unwanted activations in sleeping persons. An activation may end in an awakening, and a higher activation is of course indicated by increased awakening reactions (e.g. (SVRU 1999; Jansen et al. 1995; Maschke 1997; Griefahn 1990)). But also below the awakening threshold, considerable interferences with sleep stages including vegetative reactions (arousals) may occur (e.g. (Raschke et al. 1997)). Arousals are a necessary function to counteract hazardous stimuli or events through an activation of compensatory mechanisms, in other words to maintain the physiological balance.

Frequent arousals during sleep, caused by internal or external receptor stimuli, may lead to deformations of the biological rhythm. A deformation becomes evident in fragmented sleep processes and in changed hormone responses (e.g. cortisol nadir). A fragmented sleep process with increasing nocturnal arousals may induce a rise in the tone of the sympathetic nervous system. The results are a deterioration of sleep quality, which may lead to reduced daytime performances, sleepiness and tiredness. Long-term interferences with the circadianian rhythm have negative effects on health (Hanley et al. 1989; Zuberi-Khokar et al. 1996; Biberdorf et al. 1993; Bonnet et al. 1995; Mercia et al. 1991). Night-time protective policies should therefore not be confined to awakening reactions alone, but ought to take all aspects of noise­induced sleep disturbances into consideration, as frequent interferences with physiologically programmed sleep structures may cause adverse health effects (Raschke et al. 1997).

The presented revision of the study of Griefahn et al. (1976) shows, in agreement with evaluations of recent literature, that increasing (intermittent) flight noise-induced awakening reactions are statistically to be expected at maximum noise levels at the latest 48 dB(A), in contrast to the threshold of 60 dB(A) calculated by Griefahn et al. in 1976. A comprehensive protection of individuals against nocturnal awakenings is, however, not even given at a limit value of a maximum level 48 dB(A), because individual sensitivities towards noise immissions vary considerably. The statement of Jansen (Jansen 2000b) that with regard to the studies of Griefahn et al. (1976, 1990) the standard deviation ±7dB(A), individual noise-induced awakenings have to be expected between 53 and 67 dB(A) cannot be verified by the revision the studies of Griefahn et al. (1976), because the individual parameters are unknown in the literature evaluation by Griefahn et al.

Decision-making towards comprehensive protective policies, based on the developments in present noise effect research, is overdue. There is an urgent need (for noise effect research) to develop future-orientated protective concepts (e.g. (SVRU 1999), Tz 507). Such protective concepts should in the future not be focussed on statistical awakening threshold alone. The use of the whole dose-response curve between maximum sound levels and awakening probability can be seen as a promising approach.[35]

 
  References Top

1.AK-OGS (1999): Ergebnisprotokoll des Expertenhearings zum Thema „Notwendigkeit von Mal3nahmen im Bereich Fluglarm" des Arbeitskreises „Okologie, Gesundheit und Soziales" im Mediationsverfahren Flughafen Frankfurt/Main am 5. Oktober 1999  Back to cited text no. 1    
2.Berry, B. and G.J. Thiessen (1970): The effects of impulsive noise on sleep. National Research Council of Canada, Publication No NRC No. 11597  Back to cited text no. 2    
3.Biberdorf D. J., R. Steens, M T. W. Millar, M. H. Kryger (1993): Benzodiazepines in congestive heart failure: effects of temazepam on arousability and Cheyne Stokes respiration. Sleep 16, 529-538  Back to cited text no. 3    
4.Bonnet M. M., D. L. Arand (1995): 24-hour metabolic rate in insomnias and matched normal sleepers. Sleep 18, 581­588  Back to cited text no. 4    
5.Gadeke, R.; F.K. Daring and A. Vogel (1969): The noise level in a children's hospital and the wake-up threshold in infants. Acta Paediat. Scand. 58, 164-170  Back to cited text no. 5    
6.Gezondheidsraad (1999): Public health impact of large airports. Health Council of the Netherlands, Report No. 1999/14E, The Hague  Back to cited text no. 6    
7.Griefahn, B. (1990): Praventivmedizinische Vorschlage fur den nachtlichen Schallschutz. Zeitschrift ffur Ldrmbekdmpfung 37, 7-14  Back to cited text no. 7    
8.Griefahn, B.; G. Jansen und W. Klosterkotter (1976): Zur Problematik ldrmbedingter Schlafstorungen - eine Auswertung von Schlaf-Literatur. Umweltbundesamt Bericht 4/76  Back to cited text no. 8    
9.Hanley P. J., T. W. Millar; D. G. Steljes; R. Baert; M. A. Frais; M. H. Kryger (1989): The effect of oxygen on respiration and sleep in patients with congestive heart failure. Hun. Int. M.cal 111, 777-782  Back to cited text no. 9    
10.Hecht, K.; Maschke, C.; Balzer, H.-U.; Wagner, P.; Harder, J.; Barndal, S.; Czolbe, C.; Dahmen, A.; Greusing, M.; Knack, A.; Leitmann, T.; Wappler, I. (1999): Larmmedizinisches Gutachten DA-Erweiterung Hamburg. Institut fir Stressforschung (ISF), Berlin  Back to cited text no. 10    
11.Hofman, W. (1994): Sleep disturbance and sleep quality. Universiti t Amsterdam (Dissertation)  Back to cited text no. 11    
12.Jansen, G. (1970): Beeinflussung des natiirlichen Nachtschlafes durch Gerausche. Forschungsbericht des Landes Nordrhein-Westpfalen Nr. 2131, Westdeutscher Verlag, Koln und Opladen  Back to cited text no. 12    
13.Jansen, G. (2000a): Umwelt und Gesundheit - Kritische Wiirdigung des SRU-Sondergutachtens mit Blick auf die larmbedingten Gesundheitsbeeintrachtigungen. Zeitschrift ffur Ldrmbekdmpfung 47 (3), 103-107  Back to cited text no. 13    
14.Jansen, G. (2000b): M8 Medizinisches Gutachten fiber die Auswirkungen des Fluglarms auf die Bevolkerung in der Umgebung des Flughafens Schonefeld; Ausbau Flughafen Schonefeld, Antrag auf Planfeststellung. Flughafen Berlin Schonefeld GmbH  Back to cited text no. 14    
15.Jansen, G.; A. Linnemeier und M. Nitzsche (1995): Methodenkritische Uberlegungen und Empfehlungen zur Bewertung von Nachtfluglarm. Zeitschrift ffur Ldrmbekdmpfung 42 (4), 91-106  Back to cited text no. 15    
16.Ludlow, J.E. and P.A. Morgan (1972): Behavioural awakening and subjective reactions to indoor sonic booms. J. Sound Vibr. 25, 479-495  Back to cited text no. 16    
17.Lukas, J.S. (1972a): Effects of aircraft noise on human sleep. Ann. Ind. Hyg. Assoc. J. 33, 298-303  Back to cited text no. 17    
18.Lukas, J.S. (1972b): Awakening effects of simulated sonic booms and aircraft noise on men and women. J. Sound. Fib. 20, 457-466  Back to cited text no. 18    
19.Lukas, J.S. (1973a): Predicting the response to noise during sleep. . In: Ward, W.D. (ed): Proceedings of the International Congress on Noise as a Public Health Problem, Environmental Protection Agency No 550/9/73­008, Washington  Back to cited text no. 19    
20.Lukas, J.S. (1975a): Noise and sleep: A literature review and a proposed criterion for assessing effect. J. Acoust. Soc. Am. 58, 1232.-1242  Back to cited text no. 20    
21.Lukas, J.S. and K.D. Kryter (1968): A preliminary study of the awakening and startle effects of simulated sonic booms. NASA Report No. CR-1193  Back to cited text no. 21    
22.Lukas, J.S. and K.D. Kryter (1969): Awakening effects of simulated sonic booms and subsonic aircraft noise on six subjects, 7 to 72 years of age. NASA Report No. CR-1599)  Back to cited text no. 22    
23.Lukas, J.S.; D.J. Peeler and J.E. Davis (1975b): Effects on sleep of noise from two proposed STOL aircraft. NASA Report No. CR-132564  Back to cited text no. 23    
24.Lukas, J.S.; D.J. Peeler and M.E. Dobbs (1973b): Arousal from sleep by noises from aircraft with and without acoustically treated nacelles. NASA Report No. CR-2279  Back to cited text no. 24    
25.Lukas, J.S.; M.E. Dobbs and K.D. Kryter (1971): Disturbance of human sleep by subsonic jet aircraft noise and simulated sonic booms. NASA Report No. CR-1780  Back to cited text no. 25    
26.Maschke, C. (1997): Beeintrachtigung des Schlafes durch Larm - Kriterien fir schadliche Umwelteinwirkungen. Umweltforschungsplan des Bundesministeriums fir Umwelt, Naturschutz und Reaktorsicherheit, Forschungsbericht 97-10501213/07. Umweltbundesamt  Back to cited text no. 26    
27.Maschke, C.; K. Hecht; H. Niemann; S. Gottwald und S. Barndal (2000): Gutachterliche Stellungnahme zu den larmmedizinischen Gutachten M8 und M9 «Ausbau Flughafen Schonefeld». UBICOM, Berlin  Back to cited text no. 27    
28.Mercia, H.; J. Gaillard (1991): The EEG of sleep onset period in insomnia: a discriminant analysis. Physiol. Behav. 52, 199-204  Back to cited text no. 28    
29.Muzet, A.; J.P. Schieber; N. Olivier-Martin; J. Ehrhardt and B. Metz (1973): Relationship between subjective and physiological assessments of noise-disturbed sleep. In: Ward, W.D. (ed): Proceedings of the International Congress on Noise as a Public Health Problem, Environmental Protection Agency No 550/9/73-008, Washington  Back to cited text no. 29    
30.MV-Frankfurt/Main (1999): Mediationsverfahren Flughafen Frankfurt/Main. Gutachten fiber die Fluglarmbelastung in der Umgebung des Flughafens Frankfurt am Main fir den Ist-Zustand 1998. Hessisches Landesamt fir Umwelt (HlfU), Wiesbaden  Back to cited text no. 30    
31.Raschke, F.; J. Fischer (1997): „Arousal" in der Schlafmedizin. Somnologie 2, 59-64  Back to cited text no. 31    
32.Steinicke, G. (1957): Die Wirkung von Larm auf den Schlaf des Menschen. Forschungsberichte des Wirtschafts­und Verkehrsministeriums NRW Nr. 416  Back to cited text no. 32    
33.SVRU (1999): Der Rat von Sachverstandigen fi r Umweltfragen. Sondergutachten: Umwelt und Gesundheit - Risiken richtig einschatzen. Eigenverlag, Wiesbaden  Back to cited text no. 33    
34.Thiessen, G.J. (1969): Effects of noise during sleep. In: Welch; B.L. and A.S. Welch (eds): Physiological effects of noise. Plenum Press Publishing Corporation, New York (1970)  Back to cited text no. 34    
35.Zuberi-Khokar N., P. Hanley (1996): Increased mortality associated with Cheynes Stokes respiration in patients with conpestive heart failure. Am. J. Respirat. Crit. Care Med. 153, 272-276  Back to cited text no. 35    

Top
Correspondence Address:
C Maschke
Pücklerstraße 30, 10997 Berlin
Germany
Login to access the Email id

Source of Support: None, Conflict of Interest: None


PMID: 15703138

Rights and PermissionsRights and Permissions


    Figures

  [Figure - 1], [Figure - 2], [Figure - 3], [Figure - 4], [Figure - 5], [Figure - 6], [Figure - 7], [Figure - 8], [Figure - 9], [Figure - 10], [Figure - 11]
 
 
    Tables

  [Table - 1]

This article has been cited by
1 Do church bells disturb sleep? - A study of the effects of nightly church bell ringing on the population [Lärm von kirchenglocken]
Brink, M. and Basner, M. and Omlin, S. and Pieren, R.
Larmbekampfung. 2012; 7(1): 29-41
[Pubmed]
2 Noise in an intensive care unit
Salandin, A. and Arnold, J. and Kornadt, O.
Journal of the Acoustical Society of America. 2011; 130(6): 3754-3760
[Pubmed]
3 Work zone noise levels at Aarti steel plant, Orissa and its attenuation in far field
Kerketta, S., Dash, P.K., Narayan, L.T.P.
Journal of Environmental Biology. 2009; 30((5 SUPPL)): 903-908
[Pubmed]
4 Disturbed sleep and musculoskeletal pain in the bed partner of patients with obstructive sleep apnea
Smith, A.K.A., Togeiro, S.M.G., Tufik, S., Roizenblatt, S.
Sleep Medicine. 2009; 10(8): 904-912
[Pubmed]
5 Personal noise ranking of road traffic: Subjective estimation versus physiological parameters under laboratory conditions
Raggam, R.B., Cik, M., Höldrich, R.R., Fallast, K., Gallasch, E., Fend, M., Lackner, A., Marth, E.
International Journal of Hygiene and Environmental Health. 2007; 210(2): 97-105
[Pubmed]



 

Top